Model 1064-M 1064-L 1064-0 1064-14-L 1064-10-O 532-M 532-L 532-O 532-6-0
Power (CW) 25 to 100 90 25 14 10 35 to 100 30 to 40 8 to 13 6
Pulse stability (%rms) 2 to 3 3 2 < 2 % < 2 % 2 to 3 3 to 4 3 < 2 %
Pulse Width (ns) 160 to 220 160 140 < 40 < 40 100 to 120 120 100 < 40
Beam Pointing Stability (mrad) 20 to 30 20 15 30 30 30 to 40 20 to 40 15 to 30 30
Beam Diameter (mm) 3.0 to 3.5 2 0.55 1 0.7 2.0 to 4.0 1.5 to 2.2 0.8 to 0.9 0.8
Beam Divergence (mrad) 7 to 10 5.5 3 < 7.5 < 5.0 6.0 to 12 5.0 to 1 1 to 1.4 < 4.0
Beam Quality (M2) 12 to 25 8 1.2 < 3.0 < 1.2 16 to 45 8.0 to 12 1.2 to 1.3 < 1.2

All specifications are subject to change

For more Specifications please click



IR wavelength is used to mark a variety of materials including metals, ceramics, composites, and some plastics.

Green wavelength is ideal for composites and some plastics.

Ultraviolet is used to mark glass and some plastics.

YAG

YAG